Related Searches: Tin Bronze Copper Rod | Tin Bronze Copper Wire | Tin Bronze Copper Braided Wire | Tin Bronze Copper Conductor
Product List

Red Copper Tubing (Red Copper Tube ,Red Copper Pipe)

Description

Red copper is a kind of pure copper, which has excellent electric conductivity and plasticity. Red copper tubing is a non-ferrous metal pipe. Red copper tubing is a seamless pipe pressed and drawn by copper and copper alloy.

Application

Our red copper tubing is widely applied in water copper tubing and electric furnace tubing.

Features

Red copper pipe is hard and corrosion resistant, and it has become the first choice for modern contractors when installing tap water pipes, heating pipes and cooling pipes in all residential commodity houses. Copper pipe is the best pipe for water supply.

1. Copper tubing is economic.

Copper tubing is easy to process and connect, which saves materials and total fees when installing. Excellent stability and reliability helps to reduce maintenance.

2. Copper is light.

For rifled tube with the same inner diameter, copper tubing does not need to be as thick as the ferrous metal. Copper pipes require fewer transmission fees during installation, easier maintenance and smaller space.

3. Shape of copper can be changed.

As copper pipe can bend and transform, it is always utilized to manufacture bends and joints, and copper tubing can bend with any angle on account of its smooth bending.

4. Copper is safe.

It does not leak and generate toxic gases. It’s corrosion-resistant and not combustion-supporting. With extremely compact organizational structure, copper tube is impervious. Oil, bacteria, virus, oxygen, UV and other harmful substances are incapable of penetrating into copper tubes to pollute the water.

5. Copper enjoys stable chemical property.

It is characterized by cold resistance, hot resistance, pressure resistance, fire resistance (melting point of copper reaches 1,083 degree centigrade), making it suitable to be used in various environment for a long time. Compared with copper tubing, galvanized steel pipe is easy to corrupt, and some other materials will reduce strength rapidly under high temperature and are dangerous if used by hot water pipes. Archaeologist discovered that copper pipe used 4,500 years ago in the pyramid can still be utilized now.

Specifications

Designation Status Sectional Dimension Length Reference Standard
OD Wall Thickness ID
T2 TP2 TU2 TU1 C10200 R φ60 to 300 5 to 30
500 to 6000 GB/T1528-1997
φ95 to 120 32.5 to 35
500 to 4000 Manufacturer’s Standard
φ125 to 200 32.5 to 35
300 to 2000
φ210 to 250 32.5 to 40
300 to 1500
φ260 to 300 35 to 65
300 to 800
R φ300
φ50 to 160 300 to 700 Manufacturer’s Standard
φ370
φ5 0 to 200
φ420
φ50 to 250
M Y φ15 to 360 0.7 to 10
According to the standard GB/T1527-1997
φ38 to 300 10.5 to 17.5
500 to 7000 Manufacturer’s Standard
Y2 φ15 to 100 0.5 to 10
According to the standard GB/T1527-1997
T2 Tp2 M φ6 to 35 0.6 to 6
5800 GB/T18033-2000
Y2 φ6 to 54 0.6 to 6
Y φ6 to 219 0.6 to 6
3000
M Y2 Y φ4.76 to 25 0.3 to 1.5
3000 to 7000 GB17791-99
M φ4 to 22.23 0.3 to 1.5
80 to 12 kg (Axis Roll)
M φ7 to 9.52 0.32 to 0.36
70 to 120 kg (Rifled Tube Axis Roll) Manufacturer’s Standard
M Y φ6.35 to 19.05 0.5 to 0.7
15000 (Mosquito Coils) GB17791-99
T2 Conductor M φ8 to 17.3 0.5 to 0.7
1000000 to 8000000 (Axis Roll or Cable Drum) Manufacturer’s Standard
T2 Rectangle, Square Pipes M Y Long Side A × Short Side B × Wall Thickness: 5 to 80 × 5 to 80 × 1.0 to 10 Vertical Bar: 1000 to 5000 L ≥ 6000 for Circle Disk Manufacturer’s Standard
Note: it can be negotiated if the specification is beyond the range.

Red Copper Coils

Description

Copper tube can be applied in various environment as it is solid, difficult to corrode, heat-resistant and high pressure-resistant. Red copper coils are extensively used in heating, air conditioning, hot water supply system of industrial and civil buildings as the heat-exchange equipment in boiler room, heat exchange station and air conditioning room.

Features of Red Copper Coil

1. Heat-transfer capability and automatic cleaning ability are improved.
2. Welding points are reduced, which facilitates maintenance.
3. Compact structures to reduce volume and area.

Specifications of Red Copper Coil

Designation Status Sectional Dimensions Length Reference Standard
OD Pipe Wall Thickness ID
T2 TP2 TU2 TU1 C10200 R φ60 to 300 5 to 30

500 to 6000 GB/T1528-1997
φ95 to 120 32.5 to 35

500 to 4000 Manufacturer’s Standard
φ125 to 200 32.5 to 35

300 to 2000
φ210 to 250 32.5 to 40

300 to 1500
φ260 to 300 35 to 65

300 to 800
R φ300

φ50 to 160 300 to 700 Manufacturer’s Standard
φ370

φ5 0 to 200
φ420

φ50 to 250
M Y φ15 to 360 0.7 to 10

According to the standard GB/T1527-1997
φ38 to 300 10.5 to 17.5

500 to 7000 Manufacturer’s Standard
Y2 φ15 to 100 0.5 to 10

According to the standard GB/T1527-1997
T2 Tp2 M φ6 to 35 0.6 to 6

5800 GB/T18033-2000
Y2 φ6 to 54 0.6 to 6

Y φ6 to 219 0.6 to 6

3000
M Y2 Y φ4.76 to 25 0.3 to 1.5

3000 to 7000 GB17791-99
M φ4to 22.23 0.3 to 1.5

80 to 12 kg (Axis Roll)
M φ7 to 9.52 0.32 to 0.36

70 to 120 kg (Rifled Axis Roll) Manufacturer’s Standard
M Y φ6.35 to 19.05 0.5 to 0.7

15000 (Mosquito Coils) GB17791-99
T2 Conductor M φ8 to 17.3 0.5 to 0.7

1000000 to 8000000 (Axis Roll or Cable Drum) Manufacturer’s Standard
T2 Rectangle and Square Pipes M Y Long Side A × Short Side B × Pipe Wall Thickness: 5 to 80 × 5 to 80 × 1.0 to 10 Vertical Bar: 1000 to 5000 L ≥ 6000 Circle Desk Manufacturer’s Standard
Note: it can be negotiated if the specification is beyond the range.

Plastic Coated Red Copper Tube

Description

Plastic coated red copper tube is a kind of feed pipe that glues copper water pipe and PP-R together through heat melting. Its inner side is seamless pure red copper pipe that directly contacts water. Pure red copper pipe is helpful to sterilize water to protect the pipe.

Specification

Designation Status Sectional Dimensions Length Reference Standard
OD Pipe Wall Thickness ID
T2 TP2 TU2 TU1 C10200 R φ60 to 300 5 to 30

500 to 6000 GB/T1528-1997
φ95to 120 32.5 to 35

500 to 4000 Manufacturer’s Standard
φ125to 200 32.5 to 35

300 to 2000
φ210to 250 32.5 to 40

300 to1500
φ260to 300 35 to 65

300 to 800
R φ300

φ50 to 160 300 to 700 Manufacturer’s Standard
φ370

φ50 to 200
φ420

φ50 to 250
M Y φ15 to 360 0.7 to 10

According to the standard GB/T1527-1997
φ38to 300 10.5 to 17.5

500 to 7000 Manufacturer’s Standard
Y2 φ15to 100 0.5 to 10

According to the standard GB/T1527-1997
T2 Tp2 M φ6 to 35 0.6 to 6

5800 GB/T18033-2000
Y2 φ6to 54 0.6 to 6

Y φ6to 219 0.6 to 6

3000
M Y2 Y φ4.76 to 25 0.3 to 1.5

3000 to 7000 GB17791-99
M φ4 to 22.23 0.3 to 1.5

80 to 12 kg (Axis Roll)
M φ7 to 9.52 0.32 to 0.36

70 to 120 kg (Rifled Axis Roll) Manufacturer’s Standard
M Y φ6.35 to 19.05 0.5 to 0.7

15000 (Mosquito Coils) GB17791-99
T2 Conductor M φ8 to 17.3 0.5 to 0.7

1000000 to 8000000 (Axis Roll or Cable Drum) Manufacturer’s Standard
T2 Rectangle and Square Pipes M Y Long Side A × Short Side B × Pipe Wall Thickness: 5 to 80 × 5 to 80 × 1.0 to 10 Vertical Bar: 1000 to 5000 L ≥ 6000 Circle Desk Manufacturer’s Standard
Note: it can be negotiated if the specification is beyond the range.
Related Products